Maintenance

37

7.

Verify that the unit sits squarely on the floor. All of its feet

should be touching the floor and the unit should not rock
or wobble when in use. If not, re-level it as described in.

Monthly Maintenance

DANGER

USE EXTREME CAUTION when the rear cover of any EFX is
removed. Serious injury could result if fingers are pinched
between the flywheel spokes, cranks, movable arms, and the drive
weldment. Securing the movable arm to the crank with a clamp is
recommended. Be aware of other people within your work area
who might cause the arm to move.

Perform the following maintenance tasks every month:

1.

Clean the frame, cover and arms with water or an

approved cleaner.

2.

Wipe the exterior of the console with a damp sponge or

soft cloth, and dry with a clean towel. Keep water away
from electronic components to prevent electrical shock or
damage.

3.

Clean the touchscreen using a soft, lint-free cloth

dampened with a 91% isopropyl alcohol solution (either
as sold or diluted with an equal amount of water).

4.

Remove the rear cover. Vacuum out any debris, being

careful not to bring the vacuum cleaner nozzle too close
to any circuit board (unless your vacuum cleaner is
protected against static buildup).

5.

Check the belt tension of the step-up and drive belts.

6.

Clean and lubricate the lift motor screw with an approved

grease such as SuperLube® with Teflon® or Mobil 1®
synthetic grease (adjustable-ramp models only).

7.

Check all fasteners for proper tightness and torque.

8.

Replace all covers.

9.

Verify that the unit sits squarely on the floor. All of its feet

should be touching the floor and the unit should not rock
or wobble when in use. If not, re-level it as described in.