Uhf amplifier module bgy280 – Philips BGY280 User Manual

Page 5

Advertising
background image

2000 Nov 15

5

Philips Semiconductors

Preliminary specification

UHF amplifier module

BGY280

Fig.4

Second harmonic as a function of load
power; typical values.

Z

S

= Z

L

= 50

Ω; V

S

= 3.6 V; P

D

= 0 dBm;

T

mb

= 25

°C; δ = 2 : 8; t

p

= 575

µs.

-60

-50

-40

-30

-20

20

25

30

35

40

P

L

(dBm)

H

2

(dBc)

1710MHz

1785MHz

915MHz

880MHz

Fig.5

Third harmonic as a function of load power;
typical values.

Z

S

= Z

L

= 50

Ω; V

S

= 3.6 V; P

D

= 0 dBm;

T

mb

= 25

°C; δ = 2 : 8; t

p

= 575

µs.

-60

-50

-40

-30

-20

20

25

30

35

40

P

L

(dBm)

H

3

(dBc)

880MHz

915MHz

1710MHz

1785MHz

0

10

20

30

40

10

20

30

40

P

L

(dBm)

gain
(dB)

(6)

(4)

(5)

(3)

(1)
(2)

conversion gain

small signal gain

Fig.6

Gain as a function of load power; typical
values.

Z

S

= Z

L

= 50

Ω; P

D

= 0 dBm; V

S

= 3.6 V;T

mb

= 25

°C;

f

c

= 1747.5 MHz;

δ = 2 : 8; t

p

= 575

µs.

(1) f = 1805 MHz

(4) f = 1615 MHz

(2) f = 1842.5 MHz

(5) f = 1625.5 MHz

(3) f = 1880 MHz

(6) f = 1690 MHz

Fig.7

Gain as a function of load power; typical
values.

0

10

20

30

40

10

20

30

40

P

L

(dBm)

gain
(dB)

(1)

(6)

(5)

(4)

(3)

(2)

conversion gain

small signal gain

Z

S

= Z

L

= 50

Ω; V

S

= 3.6 V; P

D

= 0 dBm;

T

mb

= 25

°C; f

c

= 897.5 MHz;

δ = 2 : 8; t

p

= 575

µs.

(1) f = 925 MHz

(4) f = 835 MHz

(2) f = 942.5 MHz

(5) f = 852.5 MHz

(3) f = 960 MHz

(6) f = 870 MHz

Advertising