Uhf amplifier module bgy280, Fig.9 output phase at p, 5 dbm, relatively to output phase at p – Philips BGY280 User Manual

Page 6: 5 dbm; typical values

Advertising
background image

2000 Nov 15

6

Philips Semiconductors

Preliminary specification

UHF amplifier module

BGY280

Fig.8

Output amplitude modulation as a function
of load power; typical values.

Z

S

= Z

L

= 50

Ω; V

S

= 3.6 V; P

D

= 0 dBm; T

mb

= 25

°C;

∆f = 100 kHz; input amplitude modulation = 5.4%; δ = 2 : 8; t

p

= 575

µs.

0

10

20

30

40

0

10

20

30

40

P

L

(dBm)

output

AM
(%)

900MHz

1800MHz

Fig.9

Output phase at P

D

= +0.5 dBm, relatively

to output phase at P

D

=

−0.5 dBm;

typical values.

Z

S

= Z

L

= 50

Ω; V

S

= 3.6 V; P

D

= 0 dBm; T

mb

= 25

°C;

δ = 2 : 8; t

p

= 575

µs.

0

2

4

6

8

-10

0

10

20

30

40

P

L

(dBm)

AM-PM

(deg/dB)

1800MHz

900MHz

Fig.10 Noise as a function of load power;

typical values.

Z

S

= Z

L

= 50

Ω; V

S

= 3.6 V; P

D

= 0 dBm;

T

mb

= 25

°C; δ = 2 : 8; t

p

= 575

µs.

-100

-90

-80

-70

-60

0

10

20

30

40

P

L

(dBm)

noise

(dBm)

R

X

=1845MHz

R

X

=942.5MHz

Advertising