Panasonic CU-C12DKU User Manual

Page 73

Advertising
background image

How to use electronic circuit diagram

TIMER TABLE

Test Mode

Name

Time

(When test point

Remarks

Short-circuited)

Real Timer

1 hr.

1 min.

10 min.

10 sec.

1 min.

1 sec.

Time Delay Safety Control

2 min. 58 sec.

0 sec.

Forced Operation

60 sec.

0 sec.

Time Save Control

7 min.

4.2 sec.

Anti-Freezing

4 min.

0 sec.

Auto Mode Judgement

20 sec.

0 sec.

Soft Dry

OFF

6 min.

36 sec.

ON

10 min.

60 sec.

Soft Dry: 10 min. operation

Deodorizing Control

Cooling

40 sec.

4 sec.

70 sec.

7 sec.

20 sec.

2 sec.

180 sec.

18 sec.

Soft Dry

40 sec.

4 sec.

360 sec.

36 sec.

Comp. Reverse Rotation Detection

5 min.

30 sec.

Comp. ON 5 min. and above

2 min.

0 sec.

Comp./ Fan Motor Delay Timer

1.6 sec.

0 sec.

Powerful Mode Operation

15 min.

15 sec.

Random Auto Restart Control

0 ~ 62 sec.

0 ~ 6.2 sec.

73