8.10. Quiet Operation

(For Cooling Operation or cooling region of Soft Dry Operation)

•

The Quiet operation is to provide quiet/cooling operation condition compare to normal operation.

•

Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB
for Lo fan speed or 3 dB for Hi/Me fan speed against the present operation sound level.

•

Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo +
80 rpm). After that, it goes back to Lo cool (However Quiet LED remains on).

•

Manual Airflow Direction:-

−

RPM control during Lo cool

−

RPM control during Hi cool

•

Auto Airflow Direction:-

•

Quiet operation stops when:-

−

Quiet button is pressed again.

−

Stopped by OFF/ON operation button.

−

Timer OFF activates.

−

Powerful button is pressed.

−

Economy button is pressed.

−

Operation mode button is changed.

25

CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU

Advertising