Compumotor indexer, Quick test: oem650x – Parker Products OEM650X User Manual

Page 18

Advertising
background image

11

OEM650/OEM650X • INSTALLATION

OEM

s

e

r

i

e

s

REMOTE

REF

CURRENT

DUMP

VDC+

VDC-

A+

A-

B+

B-

POWER

FAULT

Power

Supply +

-

Refer to Figures 2-2 and
2-3 for specific motor
wiring instructions

OEM

Series

Motor

Compumotor

Indexer

Compumotor

To connect the OEM650 to the Compumotor
indexer, use the cable provided with the
indexer. The cable should fit into the OEM650's
25-pin D connector as shown in this figure. No
additional wiring is necessary. Refer to the
indexer's user guide for any specific instructions
associated with the Compumotor indexer.

Drive

Figure 2-6. OEM650 with Compumotor Indexer Test Configuration

OEM

s

e

r

i

e

s

REMOTE

REF

CURRENT

DUMP

VDC+

VDC-

A+

A-

B+

B-

POWER

FAULT

Power

Supply +

-

Refer to Figures 2-2 and
2-3 for specific motor
wiring instructions

OEM

Series

Motor

To connect the OEM650 to a non-
Compumotor indexer or pulse generator,
use the pinouts of the OEM650's 25-pin D
connector as shown in this figure. Refer to
the indexer or pulse generator's user guide
for any specific instructions associated with
the device.

1 Step+
2 Direction+

14 Step—
15 Direction—

Connect to non-Compumotor

Indexer or Pulse Generator

Figure 2-7. OEM650 with non-Compumotor Indexer or Pulse Generator Test Configuration

Quick Test: OEM650X

1. Complete steps 1- 6 from the OEM650 Quick Test. but do not

remove jumper #11 (Auto Test Function)

2. Connect the OEM650X to an RS-232C communications device

(i.e., computer, PLC, etc.). The OEM650X's communication
parameters are listed below:

❏ Baud Rate: 9600
❏ Data Bits: 8
❏ Stop Bit: 1
❏ Parity: None

Advertising
This manual is related to the following products: