Oem650x inputs and outputs, Step (signal 1) & direction (signal 2) outputs – Parker Products OEM650X User Manual

Page 33

Advertising
background image

INSTALLATION • OEM650/OEM650X

26

Gear Shift Input

The Gear shift input is an optically isolated input that uses and ILQ2
quad OPTO isolator. The GS+ terminal is connected to the anode of
the OPTO lead via a 681

current limiting resistor. The GS- terminal

is connected to the cathode of the OPTO lead. The OPTO requires a
minimum of 3.5 mA (approximately 3.5VDC) to ensure proper system
operation.

This function allows a user with a limited frequency generator to
achieve higher velocities while using high resolution settings. This is
accomplished by the drive multiplying each step pulse that it re-
ceives by a factor of 8. This function may be invoked on-the-fly;
however, to prevent stalling and to keep track of motor position, it
should only be invoked when the motor is not moving.

OEM650X Inputs and Outputs

OEM

s

e

r

i

e

s

REMOTE

REF

CURRENT

DUMP

VDC+

VDC-

A+

A-

B+

B-

POWER

FAULT

7

17

16

Tx

Rx

1

2

3

4

5

6

8

9

10

11

12

13

14

15

19

18

21

20

23

22

25

24

N.C.

N.C.

N.O.

N.C.

N.C.

N.C.

CW Limit

Step Output

Direction Output

CCW Limit

Home

Reserved

GND Ref.

Output #2

Fault Output

Output #1

Sequence #1

Sequence #2

Sequence #3

Shutdown

Encoder Channel A

Encoder Channel B

Encoder Channel Z

N.C.

N.C.

N.C.

Trigger Input #1

Trigger Input #2

Trigger Input #3

N.C.

N.C.

N.C.

Address Sel. #1

Address Sel. #2

Address Sel. #3

RS-232C

Slave

Drive

Slave

Drive

Customer

Equipment

Figure 2-19. OEM650X Inputs & Output Schematic

CAUTION

I/O is not OPTO isolated, I/O GND is common to VDC-.

Step (Signal 1) & Direction (Signal 2) Outputs

The OEM650X produces a step
and direction output that is
identical to the indexer's internal
step and direction signals.
These outputs can be used to
slave to another drive or to
monitor the OEM650X's position
and velocity. The Direction
output's default state is logic high. The Step output's default state is
a high, pulsing low output. The figure represents a typical configu-
ration of this output.

• Minimum high-level output: 4.26V
(Source 24mA)

• Maximum low-level output: 0.44V
(Sinks 12 mA)

ACTØ4

+5V

4.75k

Advertising
This manual is related to the following products: