RFID MAX RETRY
Check System

Error Handling = Overstrike in
the RFID CONTROL menu,
and the Label Retry count has
been exhausted.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 70.

RFID TAG ERR:
Read-Only Tag

A write was attempted on a
read-only tag.

Press PAUSE to clear the
message.
Change media to writable
tags or remove the write
command from the
application.

RFID TAG FAILED
Check Media

Error Handling = Stop in the
RFID CONTROL menu, and
the RFID encoder could not
read the RFID tag.

Press PAUSE to clear the
message.
See “Troubleshooting” on
page 70.

RFID UNLOCK CMD:
Not Supported!

An unlock command was
executed on a tag which does
not support locking.

Press PAUSE to clear the
message.
Remove the unlock
command from the
application.

RFID ACS FIELD:
Not Supported!

The ACS field was accessed
on a tag which does not
support the ACS field.

Press PAUSE to clear the
message.
Remove references to the
ACS field from the
application.

RFID KIL FIELD:
Not Supported!

The KIL field was accessed
on a tag which does not
support the KIL field.

Press PAUSE to clear the
message.
Remove references to the
KIL field from the
application.

Table 3. Control Panel Error Messages