64 Bit And 96 Bit EPC Data Formats

74

IMPORTANT

When any of these three parameters are inconsistent then
confusion is likely.

The following tables (Table 5 on page 74 for PGL and Table 6 on
page 75 fo
r ZGL) identify the consequences of mismatched criteria.

Table 5. PGL EPC Format Handling

EPC Format

(based on

header)

Selected
Tag Data

Length

Size of Data

Request (from

program)

Result

Comment

64 bit

64 bit

< 64 bit

OK

Pad 0s to left for 64 bit

64 bit

64 bit

= 64 bit

OK

As is

64 bit

64 bit

> 64 bit

Error

Data too long

64 bit

96 bit

< 64 bit

Read 96 bit

Pad 0s to left for 96 bit

64 bit

96 bit

= 64 bit

Read 96 bit

Pad 0s to left for 96 bit

64 bit

96 bit

64 bit <> 96 bit

Read 96 bit

Pad 0s to left for 96 bit

64 bit

96 bit

= 96 bit

Error

EPC incompatible with

length

64 bit

96 bit

> 96 bit

Error

Data too long

96 bit

64 bit

< 64 bit

Error

EPC incompatible with

length

96 bit

64 bit

= 64 bit

Error

EPC incompatible with

length

96 bit

64 bit

> 64 bit

Error

Data too long

96 bit

96 bit

< 96 bit

OK

Pad 0s to left for 96 bit

96 bit

96 bit

= 96 bit

OK

As is

96 bit

96 bit

> 96 bit

Error

Data too long