Alternate repair instructions step 5 – Pentair Hydrel Fixture Housing 620001 User Manual

Page 13

Advertising
background image

Rev. A 1-18-06

13

P/N 620001

Alternate Repair Instructions

STEP 5

1. Completely cover the entire entry hub, the bond wire and the post clamp with two parts underwater epoxy

putty, (supplied with this kit), to at least 1/4 inch thickness.
a. If a bonding wire is connected to the bonding lug in the fixture housing cover this connection with a listed

potting compound, (Scotchcast 2134 or equivelant).

b. This will require the pool water level to be lowered and the potted area dried.
c. Allow 30 minutes prior to applying the epoxy putty.

2. Do not cover the anode block.
3. Allow the light fixture cord to move freely within the putty.

NOTE

Cord must move freely within the putty to allow the removal of the light fixture should it ever need repair or replacement.

hn-09-11-16-98

Do not cover
anode assy.
with potting
compound

Potting
Compound

Figure 5.