background image

Rev. A 1-18-06

3

P/N 620001

Fixture Housing Entry Hub Repair Instructions.

STEP 2

1. If there is no internal bond wire as shown, skip to STEP 3.
2. If there is an internal bond wire or a non-listed potting material around the bond post, remove the potting material

completely. A non-listed potting material would be silicone, RTV, etc.
a. Be very careful not to damage the No. 8 bond wire, the screw or the post.

3. Replace the bond wire or the bonding screw if it is damaged. Then go to instruction STEP 4 and complete the

procedures through STEP 6.

hn-02-11-16-98

Fixture 2.

Light Fixture
Cord

Internal Bond
Wire

Remove bonding
lug potting
material if
present, check
that screw is
tight.