Alarm In/Out Ratings

..............................................................................................................................

Note

• Check the Operating Instructions (provided) to see if the ratings of sensors and other

external devices are compatible with the camera ratings.

...................................................................................................................................

Pin Arrangement of 4-pin Alarm Cable (accessory)

Terminal Name

Rating

Remarks

ALARM IN

5 V DC pull-up built in

ON

Short-circuit with GND (necessary

drive current is 1 mA or greater)

OFF

Open or 4 V DC to 5 V

ALARM OUT

Open collector output (internal pull-

up/maximum drive current 50 mA),

latch/pulse

Latch/pulse setting

selectable

OPEN

4 V DC to 5 V

CLOSE

1 V DC maximum

AUX OUT

Open collector output (internal pull-

up/maximum drive current 50 mA)

OPEN

Open or 4 V DC to 5 V

CLOSE

1 V DC maximum

DAY/NIGHT IN

DC 5 V pull-up built in

Terminal shared with

ALARM OUT. Can be

selected in settings

(Default setting: ALARM

OUT)

ON (black and

white)

Short-circuit with GND (necessary

drive current is 1 mA or greater)

OFF (color)

Open or 4VDC to 5V

1 Black

GND

2 Gray

AUX OUT

3 Red

ALARM OUT or DAY/NIGHT IN

4 Green

ALARM IN