Ballast, Wiring diagram–lamp operation, Features – Philips HO User Manual

Page 3: General specifications, Enclosure dimensions

Advertising
background image

LAMP

BALLAST

BLUE

YELLOW

BLACK/ORANGE

BLACK/WHIT E

RED

(HOT)

(NEUTRAL )

Yellow leads must be connected for (1) lamp operation

Wiring Diagram–Lamp Operation

Advance JOP-2S95-G T5 VHO for 2-lamp version ballast

Features

• Programmed Start ballast
• Ballast factor of 1.0 for 2-lamp version
• 277V–480V input voltage range, 50/60Hz
• 194˚F / 90˚C maximum case temperature

• -19˚F (-28˚C) minimum starting temperature
• <10% Total Harmonic Distortion (THD)
• One or two lamp operation

General Specifications

Section I — Physical Characteristics
1.1 The electronic ballast shall be furnished with integral leads color coded

to ANSI standard C82.11.

Section II — Performance Requirements
2.1 The electronic ballast shall be programmed start.
2.2 The electronic ballast shall operate from 250V–528V.
2.3 The electronic ballast shall maintain constant light output, for line

voltage variations of 10% of rated supply voltage.

2.4 The electronic ballast input current shall have Total Harmonic

Distortion (THD) of less than 10% at maximum light output
for primary lamps.

2.5 The electronic ballast shall have a Power Factor greater than 98%

at full light output.

2.6 The electronic ballast shall have a minimum ballast factor of 1.0

for primary lamp applications.

2.7 The electronic ballast lamp current crest factor shall be 1.7 or less

in accordance with lamp manufacturer recommendation.

2.8 The electronic ballast shall withstand a sustained open circuit and

output conditions without damage.

2.9 The electronic ballast shall be Sound Rated A.

2.10 The electronic ballast shall be a high frequency electronic type

and operate above 40 kHz to avoid interference with infrared
control systems, and eliminate visible flicker.

2.11 The electronic ballast shall comply with ANSI C82.11, where applicable.
2.12 The electronic ballast shall provide transient immunity as specified

in ANSI C62.41.

2.13 The electronic ballast shall provide end of life protection circuitry.
2.14 The electronic ballast shall have a minimum starting temperature

of -19°F (-28°C) for T5VHO lamps.

Section III — Regulatory Requirements
3.1 The electronic ballast shall not contain any Polycholorinated

Biphenyl (PCB’s).

3.2 The electronic ballast shall be Underwriters Laboratories (UL 935)

listed, Class P and Type 1 Outdoor; and Canadian Standards
Association (CSA) certified, where applicable.

Section IV — Other
4.1 The manufacturer shall have a fifteen-year history of producing

electronic ballasts for the North American market.

4.2 The electronic ballast shall be produced in a factory certified

to ISO 9001 Quality System Standards.

Enclosure Dimensions

Advance JOP-2S95-G T5 VHO Ballast

Advance 277V–480V (1) or (2) lamp 95W T5 VHO Ballast

Ballast Ordering, Electrical and Technical Data

Lamp

Maximum

Min.

No. of

Input

Starting

Ballast

Catalog

Input Power

Ballast

Line Current

Starting

Lamps

Volts

Method

Family

Number

ANSI (Watts)

Factor

(Amps)

Temp (˚F/˚C)

1

277

PS

Optanium

JOP-2S95-G

116W

1.1

0.42A

-19/-28

1

347

PS

Optanium

JOP-2S95-G

116W

1.1

0.35A

-19/-28

1

480

PS

Optanium

JOP-2S95-G

116W

1.1

0.24A

-19/-28

2

277

PS

Optanium

JOP-2S95-G

206W

1.0

0.74A

-19/-28

2

347

PS

Optanium

JOP-2S95-G

206W

1.0

0.59A

-19/-28

2

480

PS

Optanium

JOP-2S95-G

206W

1.0

0.43A

-19/-28

Above specifications subject to change without notice.

LAMP

BALLAST

BLUE

YELLOW

BLACK/ORANGE

BLACK/WHITE

RED

(HOT)

(NEUTRAL )

LAMP

A

. . . . . . . 1.18"

B

. . . . . . . 1.70"

C

. . . . . . 16.34"

D

. . . . . . 16.70"

New P-5904-A T5 VHO Prod Bulletin.qxd:Layout 1

9/9/08 6:08 PM Page 3

Advertising