Setup menus, User menu, Interface – Panasonic AJ-HD150FE User Manual

Page 76

Advertising
background image

– 76 –

Setup menus

USER menu

<INTERFACE>

Item

Setting

No.

Superimposed

No.

Superimposed

Description

display

display

200

PARA RUN

0000

DIS

0001

ENA

201

9P SEL

0000

OFF

0001

ON

202

ID SEL

0000

OTHER

0001

DVCPRO

0002

ORIG

203

50P SEL

0000

OFF

0001

ON

204

RS232C SEL

0000

OFF

0001

ON

205

BAUD RATE

0000

300

0001

600

0002

1200

0003

2400

0004

4800

0005

9600

206

DATA

0000

7

LENGTH

0001

8

207

STOP BIT

0000

1

0001

2

208

PARITY

0000

NON

0001

ODD

0002

EVEN

209

RETURN

0000

OFF

ACK

0001

ON

210

50P STBY

0000

OFF/ON

CMD

0001

ON

The underline on the setting item denotes the initial setting.

This selects whether two or more VTRs are to be operated in
synchronization.
0: No operation in synchronization
1: Operation in synchronization
<Note>
When operating two or more VTRs in synchronization, set all
the VTRs to 0001 (ENA). (See pages 9 and 17.)

This selects whether the 9P connector functions when the
REMOTE/LOCAL switch has been set to REMOTE.
0: Do not function
1: Function

This selects the ID information which is returned to the
controller.
0: 20 25H
1: The DVCPRO’s original ID (F0 33H) is returned.
2: The unit’s original ID (A0 50H) is returned.
<Note>
The 2(ORIG) setting should only be used when a Panasonic
controller (AJ-A900 etc, sold separately) is connected.

This selects whether the PARALLEL (50P) connector functions
when the REMOTE/LOCAL switch has been set to REMOTE.
0: Does not function
1: Functions

These settings are for selecting whether the RS-232C
connector is to function when the REMOTE/LOCAL switch is
set to REMOTE.
0: Connector does not function.
1: Connector functions.

These settings are for selecting the RS-232C communication
speed (baud rate).

These settings are for selecting the RS-232C data length.
(Unit: bit)

These settings are for selecting the RS-232C stop bit length.
(Unit: bit)

These settings are for selecting the none, odd or even for the
RS-232C parity bit.
0: Parity bit is not used.
1: An odd number of bits is used for the parity system.
2: An even number of bits is used for the parity system.

These settings are for selecting whether the ACK code is to be
returned when a command is received from RS-232C.
0: ACK code is not returned.
1: ACK code is returned.

For selecting the method used to detect the STANDBY
COMMAND signal input at the PARALLEL (50P) connector.
0: Each time active signals are detected, the STANDBY ON or

STANDBY OFF mode is selected alternately.

1: When active signals are detected in the STANDBY OFF

mode, the unit is transferred to the STANDBY ON mode.
Nothing happens if they are detected during an operation in
the STANDBY ON mode.