Contact is opened. refer to the, G.703 dte interface – Paradyne ACCULINK 336x E1 User Manual
Page 117

ACCULINK 336x E1 NTU
D-2
December 1996
3360-A2-GB20-20
G.703 DTE Interface
The G.703 DTE interface is either two BNC
connectors (Transmit and Receive) for a 75 ohm
unbalanced interface, or a DB15-type socket connector
(
) for a 120 ohm balanced interface. For
information about using Relay Contact Sense for external
DTE loopback, refer to the Extrn DLB configuration
option in the
DTE Interface Configuration Options
of Appendix C.
supplied by a DTE vendor. It is made of shielded
twisted-pair wires (22 AWG). The cable connector is a
DB15 plug. Be sure to connect the shield ground only at
the E1 NTU end to prevent ground loops.
Table D-2
G.703 DTE Connector (120 Ohm)
Signal
Pin Number
Receiver Tip from DTE
1
Receiver Ring from DTE
9
Transmitter Tip to DTE
3
Transmitter Ring to DTE
11
Relay Contact Sense Return
12
Relay Contact Sense
14
Shield Ground
2, 4
Figure D-1. G.703 DTE Cable