Paradyne ACCULINK 336x E1 User Manual

Page 67

Advertising
background image

Maintenance

4-9

3360-A2-GB20-20

December 1996

Table 4-4

(2 of 2)

Performance Registers

Register

Totals Description

Interval Description

LOFC
(Not valid for
Lp

n registers.)

The loss of frame count for the current interval.
This is a count of the number of times that an
LOF is declared. The maximum count is 255.

The total loss of frame count for the previous

x

hours, where

x is 24 hours for aggregate

performance and 8 hours for port performance.

StEvnt
(Not valid for
Lp

n or port

registers.)

The status events register records whether one
or more of the following events have occurred
at least once during the interval. The event is
identified by a letter as follows:
R – A Remote Alarm Indication has been

received on the network interface or the
G.703 DTE interface.

L – Loss Of Signal has occurred on the

network interface or the G.703 DTE
interface.

E – The Excessive Error Rate threshold has

been exceeded.

F – A Frame Synchronization Bit Error has

been detected.

V – A Bipolar Violation has been detected.

If none of these events occurred during the
interval, StEvnt=none will be displayed.

N/A

FEBE
(Only valid for
Lp

n registers.)

The number of far-end block errors (reported by
remote equipment) for the current interval. The
maximum count is 900.

The total number of far-end block errors for the

previous

x hours, where x is 24 hours for aggregate

performance and 8 hours for port performance.

Complete
(Only valid for
far-end port
registers.)

Bad line conditions or loopback tests may
prevent far-end port statistics from reaching the
E1 NTU. This field indicates whether the
15-minute interval contains 900 seconds of
statistics. If one or more seconds of far-end
statistics are missing, this field will display
Complete=No, otherwise it will display
Complete=Yes. This field is only displayed
when Far is selected from the Prt

n screen.

N/A