Indoor fan motor operation – Philips CS-E15DB4EW User Manual

Page 20

Advertising
background image

8.1.6. Indoor Fan Motor Operation

A. Basic Rotation Speed (rpm)

• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)

[Cooling, Dry, Fan]

Remote Control

O

O

O

O

O

Tab (rpm)

PSHI

SHI

Hi

Me+

Me

Me-

Lo

Lo-

SLo

SSLo

E15D

600

560

560

495

480

425

400

370

310

200

E18D

680

640

590

563

510

488

430

410

350

200

E21D

800

750

700

660

600

560

510

480

410

200

[Heating]

Remote Control

O

O

O

O

O

Tab (rpm)

PSHi

SSHi

SHi

Me+

Me

Me-

Lo

Lo-

SLo

SSLo

E15D

650

610

600

545

540

495

480

440

300

200

E18D

740

690

640

618

560

553

490

490

320

200

E21D

870

820

770

745

670

655

580

570

370

200

B. Indoor Fan Control

i. Indoor fan control operation outline

1. Cooling / Dry

20

CS-E15DB4EW CU-E15DBE / CS-E18DB4EW CU-E18DBE / CS-E21DB4ES CU-E21DBE

Advertising