Attached accessories

Applicable piping kit

CZ-4F5, 7, 10BP

Select the best location

OUTDOOR UNIT

• If an awning is built over the unit to prevent direct

sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.

• There should not be any animal or plant which could

be affected by hot air discharged.

• Keep the spaces indicated by arrows from wall,

ceiling, fence or other obstacles.

• Do not place any obstacles which may cause a short

circuit of the discharged air.

• If piping length is over 10m, additional refrigerant

should be added as shown in the table.

• This illustration is for explanation purposes only.

The indoor unit will actually face a different way.

11.2. Indoor Unit

11.2.1. SELECTING THE LOCATION FOR THE INDOOR UNIT

Provide a check port on the piping side ceiling for repair and maintenance.

• Install the indoor unit once the following conditions are satisfied and after receiving the customer approval.

1. The indoor unit must be within a maintenance space.

2. The indoor unit must be free from any obstacles in path of the air inlet and outlet, and must allow spreading of air throughout

the room.

3. Recommended installation height for indoor unit shall be at least 2.5 m.

55

CS-E15DB4EW CU-E15DBE / CS-E18DB4EW CU-E18DBE / CS-E21DB4ES CU-E21DBE