There may be some instances when water is accidently ingested into the

PVT system. Use the following instructions to dry it out before operat-

ing.
1. Move the vehicle out of the water.
2. Remove the PVT drain plug. Allow the water to drain completely.

Reinstall the drain plug.

3. Start the engine. Place the transmission in neutral.
4. Apply varying throttle for 10-15 seconds to expel the moisture and

air-dry the belt and clutches. Do not hold the throttle wide open for

more than 10 seconds.

5. Allow the engine RPM to settle to idle speed, then shift the trans-

mission into forward gear.

6. Test for belt slippage. If the belt slips, repeat the process.
7. Take the vehicle to your dealer for service as soon as possible.