Electrical, Minimax ch millivolt wiring diagram – Pentair MiniMax CH User Manual

Page 17

Advertising
background image

Rev. C 1-22-04

P/N 472128

17

Installation (contd.)

NOTE: When connecting a remote control to the MiniMax CH, you must install the low voltage

thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these
instructions will cause the thermostat relay to react erratically.

.

Figure 19.

ELECTRICAL

MiniMax CH Millivolt Wiring Diagram

WHT

GAS VALVE

ORN

WHT

HI-LIMIT

OFF

SPA

WHT

WHT

SHUT-OFF

SAFETY

SWITCH

PRESS

WHT

POOL

PILOT
GENERATOR

THERMAL
CUT-OFF

TH

PP

TH/PP

POT 1

THERMOSTAT BOARD

POT 2

TH/PP

PP

POT

SENSOR

SEN

TH

WHT

MINIMAX WIRING DIAGRAM (MILLIVOLT) DUAL THERM
(HONEYWELL ELECTRONIC)

IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY UL OR CSA (IF CANADA)
APPROVED WIRE, 18 GAUGE, 600V, 105 C˚ TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE
REPLACED WITH UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 125 C˚ TEMPERATURE RATING.
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR
SUPERCEDING LOCAL (WIRING) CODES.

WHT

RED

Advertising