Installation (contd.), 3 wire remote 2 wire remote – Pentair MiniMax CH User Manual

Page 31

Advertising
background image

Rev. C 1-22-04

P/N 472128

31

Installation (contd.)

SPA

COM

POOL

TPROBE

OUT

RETURN

24 VAC

HILMT

IGNITION MOD

EXT SWITCH

THERMOSTAT CIRCUIT BOARD

JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH

POOL/OFF/SPA

FRONT PANEL

THERMOSTAT SELECT SWITCH

TFUSE

VALVE

PRESS

SPA

COM

POOL

TPROBE

OUT

RETURN

24 VAC

HILMT

IGNITION MOD

EXT SWITCH

THERMOSTAT CIRCUIT BOARD

JUMPER REQUIRED IF NO 2 WIRE REMOTE SWITCH

POOL/
OFF/SPA

FRONT PANEL

THERMOSTAT SELECT SWITCH

TFUSE

VALVE

REMOTE POOL/OFF/SPA

THERMOSTAT SELECT SWITCH

PRESS

NOTE: When connecting a remote control to the MiniMax CH, you must install the low voltage

thermostat wires in separate conduit from ANY line voltage wires. Failure to follow these
instructions will cause the thermostat relay to react erratically.

.