Aj8r/3, Aj8r, Specifications – Panasonic AJ8R User Manual

Page 3: Characteristics

Advertising
background image

AJ8R

7

SPECIFICATIONS

1. Contact rating

Remark: The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating.

Voltage

Resistive load

(pf = 1)

Motor load

(EN61058-1)

(pf = 0.6)

Inrush load

125V AC

16A

160A (8.3ms)

125V AC

10A

4A

2. Coil rating

Remark: If the rated voltage is applied to the coil for more than ten seconds or the maximum voltage is applied for more than one second, coil perfor-

mance will deteriorate.

Nominal Voltage

*(Max. 10 sec)

Drop-out voltage

(at 20

°

C

68

°

F

)

Nominal operating current

[

±

10%] (at 20

°

C

68

°

F

)

Coil resistance

[

±

10%] (at 20

°

C

68

°

F

)

Maximum voltage

(Max. 1 sec)

5V DC

Max.4.5V

Min.0.5V

725mA

6.9

5.5V

12V DC

Max.10.8V

Min.1.2V

300mA

40

13.2V

24V DC

Max.21.6V

Min.2.4V

150mA

160

26.4V

3. Characteristics

Remark: Test conditions are in accordance with EN61058-1,UL1054 and JIS C 6571

Electrical life

Manual operation

Min.10

4

(at 7 cpm.,at rated load)

Coil operation

Min.10

3

(at 7 cpm.,at rated load)
Min.5

×

10

4

(at 7 cpm. 5A 125V AC resistive load)

Mechanical life

Min.5

×

10

4

(at 20 cpm.)

Initial contact resistance
(By voltage drop at 1A, 2 to 4V DC)

Max. 100m

Initial insulation resistance

Min. 100m

(at 500V DC measured by insulation resistive meter)

Initial breakdown voltage

Between contacts

2,000 Vrms

Between coil and contact

4,000 Vrms

Ambient temperature

0

°

C to +60

°

C

32

°

F to +140

°

F

(Not freezing below 0

°

C

32

°

F

)

Ambient humidity

Max. 85% R.H.

Vibration resistance

10 to 55 Hz at single amplitude of 0.75mm

Shock resistance

Functional

Min.294m/s

2

{30G}

(Contact opening Max. 1ms)

Destructive

Min.980m/s

2

{100G}

Tensile terminal strength

.250 Quick-connect terminal Min. 98N{10kgf}/min.
(Pull & push direction)

Actuator strength

39.2N{4kgf} for 1min. operating direction

Contact release time

Max. 100ms (at rated voltage)

Initial operating force
* Reference value

4.9N or less (Max. 500gf or less)
Setting force after reset has been released: Max. 6.86N or less (Max. 700gf or less)

Flame retardancy

UL94V-0

Tracking resistance

Min. 175

Unit weight

Single pole, single throw: Approx. 17g

.60oz

Single pole, double throw: Approx. 19g

.67oz

Double pole, single throw: Approx. 20g

.71oz

03/2005