Step procedure – Paradyne BitStorm IP DSLAM 1900 User Manual

Page 80

Advertising
background image

2. BitStorm 1900 Installation and Testing

2-64

BitStorm 1900 Installation and Maintenance Guide

1900-A2-GN20-00

Task 009: Installing Voice/Data w/Filter 66-Block

Connections

Use this procedure to connect the BitStorm 1900 to the EtherLoop
cross-connect in applications where voice/data service is required with
a Filter 66-Block.

Requirements

This procedure requires the following tools and materials:

•

5 BitStorm 1900 cable harnesses

•

5 intermediate cables

•

Cross-connect block(s) of the same type used in the existing main
distribution frame (MDF)

•

Cross-connect punch-down tool

•

Jumper Wire (24 AWG)

"Appendix B. Cabling Specifications," on page 115 contains the
complete specifications for the cables and wiring required in this
procedure.

Step

Procedure

1.)

Mount 66-blocks on wall in an appropriate area for running

jumpers.

2.)

Verify the room position on frame blocks.

3.)

Replace jumpers to 66-Filter Block and retest phone lines.

4.)

Refer to Figure 2-14, "Voice/Data Filter 66-Block Connections for

10306 CO Modems," on page 65, and Figure 2-15, "Voice/Data
Filter 66-Block Connections for 10224 CO Modems," on page 66
.

Advertising