The dsl clear errcntrs command clears the error counters.

Remote Console

Provided that there is a DSL link to a second 3088, a user may login to
the first 3088’s console and enter the remote console command to
access the second 3088’s console. Using this remote console feature,
the user can configure and query the status of the second 3088 from a
remote location. When the user is finished with the remote console, the
logout command can be used to return to the local console.

Example Command Line Interface Session

password: ******

> system set circuitid “3088 Circuit ID”

> system set timeslots 3

> system set clockmode internal

> dsl set annex b

> dsl set lineprobe disabled

> system save config

> dsl start

> system show status

leds: power: on dsl: on tm/er: off

dsl test mode:

ber status: idle

errors: 0

time: 0

front panel switches: sw1: normal sw2: normal

dsl link state: success

configuration mode: software

> dsl show status

link state: success

sync state: in sync

link speed: 192k

error counters:

crc: 0

losw: 0

tx fifo full: 0

tx fifo empty: 0

tx fifo slip: 0

tx stuff: 0

rx fifo full: 0

rx fifo empty: 0

rx fifo slip: 0

line condition: good

noise margin: 3.5

> remote console