Lamp and temp indicators, Managing the indicated problems, Nglish - 39 – Panasonic PT-LB75U User Manual

Page 39: Jlamp indicator j temp indicator, Maintenance

Advertising
background image

E

NGLISH - 39

Maintenance

LAMP and TEMP Indicators

If a problem should occur with the projector, the LAMP and/or TEMP indicators
will inform you. Manage the indicated problems as follow.

1. Confirm the status of all indicators and projector, and switch off the

projector in proper way.

See “Switching the projector on/off” on page 18.

2. Find out the cause of the problem by status of the LAMP and/or TEMP

indicators.

3. Follow the instruction for each indication below and solve the problem.
4. Turn on the projector in the correct way and confirm the indicator is not

indicating a problem any longer.

J

LAMP indicator

J

TEMP indicator

Managing the indicated problems

NOTE:

• If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center.

Indicator

Illuminating red

Flashing red

Problem

LAMP RUNTIME has
reached 2 800 hours.

LAMP circuit failure, abnormal function or the lamp unit is damaged.

Cause

Lamp unit will run out
soon and needs to be
replaced.

The projector is switched
on again too soon.

LAMP circuit failure,
abnormal function.

Lamp unit is damaged.

Remedy

See “Replacing the Lamp
unit” on page 41.

Let the lamp unit cool
down and turn on the
projector after
90 seconds.

Switch off the projector
and contact an Authorized
Service Center.

See “Replacing the Lamp
unit” on page 41.

Indicator

Illuminating red while projecting and the alert will be displayed.
Flashing red and power is turned off

Problem

The temperature inside and/or outside the projector is abnormally high.

The projection may becomes darker than usual.

The internal fan operational noise may be louder than usual.

Cause

The ventilation openings
are covered.

The room temperature is
too high.

The filter is excessively
dirty and the ventilation is
poor.

The projector is located at
1 400 - 2 700 m (4 593 -
8 858 ft).

Remedy

Remove the object(s)
from the ventilation
openings or clear around
the projector.

Reinstall the projector in
temperature controlled
place. See page 48.

Clean the filter in the
proper method. See
page 40.

Turn on the projector

*1

and set the ALTITUDE to
HIGH. See page 35.

*1. The projector will perform 2 minutes with LOW setting at high elevation.

LAMP TEMP