Great White Installation and User’s Guide

Optional Installation

(continued)

5. Install vacuum regulator

WARNING!

Hazardous suction. Can cause entrapment with severe personal injury or drowning.

To install the vacuum regulator, insert the vacuum regulator and reducer cone in the skimmer (Figure 17).

To prevent water from flowing through the top of the vacuum regulator, attach the regulator cap to the vacuum
regulator (Figure 18). Attach the end of the hose to the vac port fitting installed in the dedicated vacuum line
(Figure 17).

Vacuum

Regulator

Regulator Cap

Reducer Cone

To Pump

Skimmer

Figure 18: Vacuum regulator installed in the skimmer with the regulator cap attached

Water

Level

1900 0405

Reducer

Cone

Vacuum

Regulator

with Regulator

Cap attached

Skimmer

Gate valve for

vacuum port must

be fully open

Attach hose to

vac port

Figure 17: Vacuum regulator and reducer cone inserted in skimmer

Advertising