10

Great White Installation and User’s Guide

Optional Installation

(Continued)

6. Check Flow

With the main drain closed, and one end of the hose attached to the vac port fitting installed in the dedicated
vacuum line, insert the flow gauge into the other end of the hose. Keep the hose and flow gauge
underwater. Turn on the pump. With the pump running, adjust the vacuum regulator (in your skimmer) until
the indicator on the flow gauge is between minimum and maximum flow (Figure 19). Remove the flow
gauge and proceed to step 7.

7. Connect Hose to the Cleaner’s Swivel Assembly

Connect the large hose cuff (Figure 20) of the leader hose to the swivel assembly on the cleaner head.
Push the cleaner into the pool and let it sink to the bottom (Figure 21).

Disc Indicator

Figure 19

Figure 20

Large hose cuff
of leader hose
designed to connect
to swivel assembly
(See “Hose Assembly”
on Page 3)

Figure 21

8. Turn the pool pump on

After completing the installation, turn the pool pump on and allow it to run for a couple of minutes to ensure
that all air cycles out of the system.