North Star M157305H User Manual

Page 9

Advertising
background image

9

V.) Getting Started

IMPORTANT: Proper initial installation of equipment
will assure more satisfactory performance, longer
service life and lower maintenance cost.

Make sure the pressure washer is on a level surface and
in a protected area where it is not readily influenced by
outside forces such as strong winds, freezing
temperatures, rain, etc. Locate the pressure washer for
easy access for filling fluids, adjustments and
maintenance.
It is recommended that a partition be made between the
wash area and the pressure washer to prevent direct
nozzle spray from coming in contact with the pressure
washer. Moisture reaching the equipment will reduce the
pressure washer’s service life.

V.) Venting

DANGER: Do not run machine indoors or in an
enclosed area without adequate ventilation or in
areas where flammable vapors (gasoline, solvents,
etc.) may be present. Do not vent exhaust gases into
a wall, a ceiling or a concealed space.
CAUTION: All venting must be in accordance with
applicable federal and state laws and local
ordinances. Consult local heating contractors.

Poor draft will cause the pressure washer to soot and not
operate properly. When selecting the location for
installation, beware of poorly ventilated locations or areas
where exhaust fans may cause an insufficient supply of
oxygen. Proper combustion can only be obtained when
there is a sufficient supply of oxygen available for the
amount of fuel being burned. If it is necessary to install a
unit in a poorly ventilated area, outside fresh air may
have to be piped to the burner and a fan installed to bring
sufficient air into the unit





VI.) Oil Burner

Burner Air Adjustment: The oil burner is preset and
performance tested at the factory (elevation 1100 feet).
A one-time initial correction of the burner for your
location will pay off in economy, performance and
extended service life.



1.) Turn the pump and heat switches on (Refer to

Operation” for details). Have someone operate the
spray gun so the burner fires.

2.) Loosen the locking screw and close the air band until

black smoke appears from the burner exhaust vent.
Note the position of the white arrow on the air band.

3.) Slowly open the air band until white smoke just starts

to appear.

4.) Turn the air band half way back to the black smoke

position previously noted. Tighten the locking screw.

5.) Fine tune the burner air by loosening the shutter lock

screw and turning the shutter until the exhaust is
cleanest. Tighten the shutter lock screw.




CAUTION: If white smoke appears from the burner
exhaust

vent

during

start-up

or

operation,

discontinue use and readjust air bands.


Partition

Locking

Screw

Air Band

Burner

White
Arrow

Shutter Lock

Screw

Shutter

Advertising