6 electrical connection – Network Computing Devices JRC 1500 MKII User Manual

Page 22

Advertising
background image

15

3.6

ELECTRICAL CONNECTION

3.6.1 DC POWER CABLE

The RADAR 1500 MK

2 will work with any electrical supply within the 10.2

to 16 V range, since it contains a power regulator circuit. Connect the power

cable to a DC source capable of supplying at least 3.5 A. The power cable

should normally be wired through a circuit breaker. The red lead wire of the

power cable must be connected to the positive source terminal and the black

lead to the source negative terminal. The shielded wire is be connected to Boat

Main ground. Should the power connections be inadvertently reversed, a pro-

tective fuse will blow. In this event, check the input power leads for correct

polarity with a VOM and reconnect the leads in their correct polarity. Replace

the fuse. The fuse is located in the power cable. [NORMAL-BROW FUSE (5

A) SHOULD BE SPECIFIED]

3.6.2 EXTERNAL SYSTEM INTERFACE

The RADAR 1500 MK

2 will interface with any NAV-AID (GPS or LORAN)

and compass with the standard NMEA0182 or NMEA0183 output. The inputs

from the NAV-AID must be digital data conforming to the NMEA0183 formats

to drive various radar features such as waypoint mode. If more than one data

type is present at the radar input (for example; compass and NAV-AID) a prior-

ity system has been established in the radar’s software to respond to the inputs

in driving the features. The assigned priorities are set in this manner:

HEADING:

1. Compass (NMEA0183 “HDG,HDM,HDT,VHW”)

2. NAV-AID (NMEA0183 “RMC,RMA,VTG”)

POSITION:

1. NAV-AID (NMEA0l83 “RMC,RMA,GLL,GTD”)

SPEED:

1. NAV-AID (NMEA0183 “RMC,RMA,VTG”)

2. Compass (NMEA0183 “VHW”)

WAYPOINT:

1. NAV-AID (NMEA0183 “RMB,BWC”)

Using the outline of FIG. 3-7, FIG. 3-8 as a guide, connect the RADAR 1500

MK

2 to your NAV-AID and compass.

INSTALLATION

Advertising