14 setting guard – Network Computing Devices JRC 1500 MKII User Manual

Page 37

Advertising
background image

30

4.14 SETTING GUARD

The guard zone alarm is effective for alerting the operator to targets approach-

ing his own ship. An alarm is sounded when any (apparent) target returning an

echo above the noise threshold is detected. If sea clutter, or other incidental

echoes trip the alarm, adjust the gain control and/or the sea clutter to avoid this

false alarming.

Press the JOYSTICK to display the menu sheet.

Select GUARD-ON and press the JOYSTICK. The radar display returns to

the normal video presentation.

Corsor appears on the PPI screen and shows the distance and the azimuth of

the Maker. It displays the distance help line and the azimuth help line of the

dotted line.

Move the cursor to the desired guard

zone start point using the JOYSTICK

and then press the JOYSTICK again.

The distance help line and the azimuth

help line of the dotted line are displayed

in the fixation in the start point posi-

tion at this time.

Next, move the cursor to the desired

guard zone Width point of your Guards

zone then press the JOYSTICK con-

trol.

It displays the distance help line of the

dotted line which is new at this time.

Next, move the cursor to the desired

end point of your guard zone then press

the JOYSTICK control. A ring in the

distance range is displayed by the solid

line at this time.

To turn the GUARD function Off,

select the GUARD-OFF on the Menu

sheet.

OPERATION

THE DISTANCE
HELP LINE

CURSOR

THE AZIMUTH
HELP LINE

START POINT (cf.

)

CURSOR

START
POINT

THE NEW
DISTANCE
HELP LINE

GUARD ZONE WIDTH (cf.

)

END
POINT

END POINT (cf.

)

START
POINT

Advertising