a hearth is not necessary but is recommended for aesthetic purposes.

the minimum distance from the top of the appliance that the

mantel can be installed is 10", at any depth.

4.4.1 Power supply service must be completed prior to finishing to avoid reconstruction.

4.4.2 appliance vents and air openings cannot be covered in any circumstances.

figurE 4.3

4.1 hearth

4.2 cold climate installation

!

WARNING

It is MANDATORY to have an insulated wall behind the fireplace, when the fireplace is being installed

on an outside wall or chase.

4.3 minimum mantel clearances

4.4 finishing checklist

!

WARNING

Risk of fire, maintain all specified air space clearances to combustibles. Failure to comply with

these instructions may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e.

back, side, top, vent, hearth, mantel, front, etc.) are clearly maintained.

When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to

prevent discolouration.

tp - cold climate Warning