Binary (BCD)

HEX

Register
Address

Comments

0 0 0 0 1 0 0 1

09

word address 9 for minute alarm

0 0 0 1 0 1 0 1

15

09

minute alarm enabled and set to 15 minutes

1 0 0 0 0 0 0 0

80

0A

hour alarm is disabled

1 0 0 0 0 0 0 0

80

0B

day alarm is disabled

1 0 0 0 0 0 0 0

80

0C

weekday alarm is disabled

generate

I

2

C start condition (repeated start)

1 0 1 0 0 0 1 0

A2

I

2

C slave address, write

0 0 0 0 0 0 0 1

01

word address 1, next bytes are data

0 0 0 0 0 0 1 0

02

01

Control/status 2, clear alarm flag and enable alarm
interrupt

generate

I

2

C stop condition

Remark: The interrupt is only set at the counter transition from 14 to 15. This is indicated
by the dashed line in Fig 11. The interrupt has to be reset by software.

Fig 11. Alarm function