Partial circuit switch down, Nxp semiconductors – NXP Semiconductors UM10301 PCF2123 User Manual

Page 38

Advertising
background image

NXP Semiconductors

UM10301

User Manual PCF85x3, PCA8565 and PCF2123, PCA2125

UM10301_1

© NXP B.V. 2008. All rights reserved.

User manual

Rev. 01 — 23 December 2008

38 of 52

001aai849

SMD

CRYSTAL

SDA

CLK

V

DD

SCL

V

SS

OSCO

OSCI

INT

layer 1

ground via

GND area

PCF8563TS

bypass

capacitor

oscillator

capacitor

guard ring

Fig 15. PCB layout proposal for PCF8563 using SMD components and guard ring

Remark: Take precautions when cleaning PCBs containing tuning fork crystals using
ultrasound. The resonance vibration may damage the crystal. Consult the supplier of the
crystal in case of doubt.

15. Partial circuit switch down

The I

2

C-bus RTC circuits PCF8563, PCA8565 and PCF8593 have on the pads SDA,

SCL and

INT

a diode clamping circuit without an upper clamping diode to V

DD

, refer to

Fig 16.

Therefore it is possible to partially switch off V

DD

such that the RTC is powered down or

working at a lower supply voltage than the rest of the circuit without the risk that via such
(upper) clamping diodes SDA, SCL and INT would be pulled down as well.

The other way around with only the RTC powered in order to keep time and the rest of
the circuit switched off will be a more common situation. If during normal operation the
complete application is powered by a certain V

DD

of for example 3.3 V or 5 V, then during

standby just the RTC can be operating and powered from a backup source as discussed
in Chapter 13. See Fig 16 and Fig 18 plus Fig 19.

PCF8583 has no protection diode from

INT

to V

DD

but has protection diodes from the I

2

C-

bus pins to V

DD

! Battery backup will work, but with the RTC powered down the I

2

C-bus

may get stuck.

The SPI-bus RTC circuits PCF2123 and PCA2125 have on pins SDI and SCL only one
clamping diode from V

SS

to the pin. On pin SDO an additional clamping diode to V

DD

is

integrated. This allows for partial circuit switch down where the RTC still runs and the
rest of the application is powered down.

Advertising
This manual is related to the following products: