Troubleshooting guide, Any questions, comments, problems or parts orders – Northern Industrial Tools 157494 User Manual

Page 18

Advertising
background image

18

Troubleshooting Guide

Water Heater Will Not Run - No Power

Causes

Solutions

Machine not plugged in

Plug machine in.

GFCI tripped

Make sure machine is dry. Press RESET on the GFCI.

Machine turned OFF

Turn heat switch ON.

Line circuit breaker tripped

Check for tripped circuit breaker in building.

GFCI Trips During Operation

Causes

Solutions

Voltage too low

Check the voltage.

Extension Cord

Make sure connections are dry and off of the ground. Check extension
cord section on page 3 for more guidelines.

Burner Will Not Fire

Causes

Solutions

Electrodes corroded or improperly spaced

Clean electrodes and reset spacing. See Electrode section on page 15.

Damaged flow switch

Replace flow switch. Call Customer Service.

Smoke From Heat Exchanger

Causes

Solutions

Air band not adjusted properly due to
different elevation

Adjust the air band until the burner burns cleanly. See Oil Burner under
Installation Instructions.

Poor quality fuel

Use Kerosene for the cleanest burn.

Water Not Heating Sufficiently

Causes

Solutions

Scale build-up in coil

See Coil Descaling under Maintenance Instructions.

Coil is full of soot

See Coil Desooting under Maintenance Instructions.

Safety Relief Valve Sprays Water

Causes

Solutions

Pressure Washer/Burner Control Problem

Call Customer Service.

Poor Or No Detergent Supply

Causes

Solutions

Soap control knob set too low.

Adjust soap control knob.

Inadequate detergent supply

Refill detergent container. Make sure chemical strainer is fully submerged.

High pressure hose too long

Use less hose. Move machine closer to the work.

Chemical strainer or injector clogged

Clean the strainer and injector. Always start with a clean detergent
container. Run clean water through the injector after each use.

Any Questions, Comments, Problems or Parts Orders

In the United States

In the United Kingdom

NorthStar Customer Service

Call 02392639752

Call 1-800-270-0810

Northern Tool and Equipment Co. (UK) Ltd.

Hours: Monday - Friday 7:00 AM to 5:30 PM

Unit 2, Keel Close,

Saturday 7:30 AM-11:30 AM Central Time

Portsmouth, Hants PO3 5QD, England

Advertising