Troubleshooting, Warning, Problem cause solution – North Star MTBSL User Manual

Page 32

Advertising
background image

Troubleshooting

32

WARNING

Before troubleshooting or attempting to service, read the following safety rules to
avoid accidental exposure to chemical and also risk of electric shock.

Note: A reserve, clean container capable of holding at least 16 gallons (Item# 28517) or 26 gallons

(Item # 28518) should be kept for use when the sprayer tank needs to be emptied temporarily for
repairs. It is advisable to purchase a reserve tank suitable for pesticide storage from Northern Tool
and Equipment for use in these circum stances. The container should be properly labeled as to its
contents if it is used.

Before attempting to service the sprayer:

1. Personal

prote ctive
e quipment

Wear pe rsonal prote ctive e quipment as dire cte d on the chemical label while
se rvicing your spraye r.

2. Re vie w

trouble shooting
table

Re vie w the Trouble shooting Table below for the type of problem you are
expe riencing.
However, DO NOT attempt to repair until the steps listed below
are followed.

3. Empty and flush

If the cause liste d for your problem is Clogge d intake tube, Clogge d suction
strainer, or Worn spray gun nozzle :
empty the tank and flush the sprayer with
water as directed in the section, “ Operation – Step Four”.

- In order to avoid accidental exposure to chem icals, never attempt to unclog
the intake tube or suction strainer, or service the spray gun nozzle, until the
tank has been em ptied and the sprayer flushed with water.

4. Disconne ct

powe r/relie ve
pressure

Disconne ct power to the spraye r and be sure all system pressure is relie ve d
by squeezing the gun trigge r.

5. Perform re pairs

Follow the dire ctions provide d in the troubleshooting table to re pair the
spraye r.

NOTE: Never try to unclog the sprayer nozzle by blowing through it.

6. Te st afte r

se rvicing

Afte r se rvicing, ALW AYS test the spraye r for leaks with plain water be fore
using.

PROBLEM

CAUSE

SOLUTION

Bad electrical connection

Check battery connections

Short in wires

Check condition of wires

Pump will not turn on

Low voltage

Check voltage

Worn spray gun nozzle

Replace spray gun

Low pressure

Worn boom nozzle

Replace boom nozzle

Clogged intake tube

Remove obstruction

Clogged suction strainer

Clean suction strainer

Low flow

Low voltage

Check voltage

Clogged intake tube

Remove obstruction

Suction strainer clogged

Clean suction strainer

Poor spray distribution

Worn spray gun nozzle

Replace spray gun

Pump cycles while not spraying

Leak in the system

T ighten leaking hose clamps or
fittings, replace spray gun

Advertising