Appendix 19

5 Appendix

5.1 Maintenance

Periodically check that the cables are secure and that the

connectors have not worked their way loose.

5.2 Troubleshooting

These simple checks should be carried out before seeking

technical assistance and may save time and expense.

General Symptom

Possible Cause

Remedy

Unit will not switch on

Faulty connector to power

Fuse has blown

Check power

connection

Replace fuse and check

power supply

No GPS Position fix

Antenna or cable problem

Check antenna cable

and connections

No AIS transmission

MMSI not entered

Transmit disabled

Enter MMSI number

(see chapter )

Enable Transmit (see

section 4.)

No reception of

NMEA018-HS

RS cable problem

RS485 cable problem


Check cables

No reception of

SimNet/NMEA000

data

SimNet/NMEA cable

problem

Check SimNet/NMEA

cables

Check power cables

5.3 Accessories

The following accessories are available from local Navico

agents:

VA14*

VHF AIS antenna - S/S whip with 0 metres

Cable, terminated in a PL59 plug.

* One off required for operation