Ato logic ato logic chart – NAD C 272 User Manual

Page 7

Advertising
background image

GB

7

The C 272 amplifier may be turned on in any one of three discrete ways
for complete system flexibility: From the front-panel switch, the 12V-
TRIGGER
circuit, or by a “SLEEP/WAKE” signal-sensing circuit. The
ON/OFF power control is managed by the Automated Turn-On logic or
ATO Logic circuit that requires the amplifier to be switched back to
standby in the same manner by which it was activated. In other words,
if the amplifier is switched on via a 12V-control signal, it cannot be
switched to standby via the front-panel switch, it must wait for removal
of the 12V-control signal. In practice, you probably would use only one
of the methods once the NAD C 272 amplifier is installed.

Amber LED over

front power switch

Green

SWITCH LED

Green

12V-TRIGGER LED

Green

SENSE LED

Amber LED over

front power switch

Green

SWITCH LED

Green

12V-TRIGGER LED

Green

SENSE LED

OFF

OFF

OFF

OFF

VACATION switch set to OFF

SWITCH

12V TRIGGER

Amber LED over

front power switch

Green

SWITCH LED

Green

12V-TRIGGER LED

Green

SENSE LED

SLEEP/WAKE

Amber

OFF

OFF

OFF

VACATION switch set to ON

Green

ON

OFF

OFF

Press front power switch with
VACATION switch set to ON

Amber

OFF

OFF

OFF

Press front power switch with
VACATION switch set to ON

OFF

OFF

OFF

OFF

VACATION switch set to OFF

Amber

OFF

OFF

OFF

VACATION switch set to ON

Amber

OFF

OFF

OFF

12 V INPUT TRIGGER = 0V with
VACATION switch set to ON

Green

OFF

ON

OFF

12V INPUT TRIGGER = 12V with
VACATION switch set to ON

OFF

OFF

OFF

OFF

VACATION switch set to OFF

Amber

OFF

OFF

OFF

VACATION switch set to ON

Amber

OFF

OFF

OFF

SLEEP/WAKE SENSE DEFEAT switch
set to SENSE DEFEAT with VACATION
switch set to ON

Green

OFF

OFF

ON

SLEEP/WAKE SENSE DEFEAT switch
set to SLEEP/WAKE and any source
input greater than 20mV with
VACATION switch set to ON

ATO LOGIC

ATO LOGIC CHART