Quick start - physical installation, Installing the nortel wlan security switch, Tabletop installation – Nortel Networks 2300 Series User Manual

Page 15: Equipment rack installation, Quick start — physical installation

Advertising
background image

15

Nortel WLAN - Security Switch 2300 Series Quick Start Guide

Quick Start — Physical Installation

This section describes how to physically install a WSS. For more information about physical installation, see Nortel
WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide
.

Installing the Nortel WLAN Security Switch

Estimated timing: 10 minutes

A WSS can be installed on either a tabletop surface or in an equipment rack.

Table 2

outlines which installation

methods are available for each WSS model.

When choosing a location for the WSS, ensure that:

The power outlet is within 1.82 m (6 ft) of the device.

There is proper heat dissipation from and adequate ventilation around the
switch.

Tabletop Installation

Step

Action

1

Ensure that the table surface supports at least 3 kg (6.6 lb).

2

Carefully turn the WSS upside down on a clean work surface with no debris.

3

Wipe the four placement locations for the rubber feet to clear away any oil or dust.
Each location area is marked with an ‘X’.

4

Attach the four rubber adhesive feet over the ‘X’s.

5

Turn the WSS right-side up, and place the switch in position on the table.

End

Equipment Rack Installation

Step

Action

1

Remove the four bracket screws from each side of the WSS.

2

Align a bracket over the screw holes:

For a front-mount equipment rack, align the bracket so that the bracket flange is
flush with the WSS front panel and away from the switch.

For a center-mount equipment rack, align the bracket so that the bracket flange
is located near the center screw holes, as shown in

Figure 2

.

Table 2: Installation methods

WSS model

Tabletop

Front-mount rack

Center-mount rack

2350

X

2360/2361

X

X

2380

X

X

X

2382

X

X

X