Nortel Networks 2300 Series User Manual

Page 22

Advertising
background image

22

NN47250-300 (320655-E

Version 02.01)

Connecting to copper gigabit devices (WSS 2380 and WSS 2382 only)

Complete the following procedure to install a GBIC.

Step

Action

1

Insert a Cat-5 cable with a standard RJ-45 connector into the port’s copper interface.
The Cat-5 cable can use straight-through or crossover signaling.

2

Access the WSS CLI using the serial console port, as described in

“Powering on a

2380” on page 18

.

3

Enter enable to access the configuration level of the CLI.

The password to gain access to privileged mode is not set. When prompted for the
password, press Enter to continue.

4

Enter set port media-type <port-list> rj45 to set the active interface on the port to
RJ-45 (copper).

5

Observe the lower LED to the left of the port:

If the LED is solid green, the 1000-Mbps link is operational.

If the LED is blinking green, traffic is active on the 1000-Mbps link.

If the LED is unlit, the link is not operational. Check the cable and verify that the
device at the other end of the link is operational.

End

Advertising