Napco Security Technologies GEM-DXK3 User Manual

Page 17

Advertising
background image

17

F U N C T I O N M E N U

9.

Reset System Trouble?

System troubles display and sound at the keypad. Correcting the trouble will clear most
indications, however the following error codes will require manual reset: E11; E13; E19;
E20 and E22. (See SYSTEM TROUBLE ERROR CODES for a description of error
codes.)



10.

Reset Sensor Watch Failure

(Sensor Watch programmed? ‰YES ‰NO).

Your system may have been programmed for Sensor Watch, a feature which supervises
the motion sensors in the system. If a Sensor Watch failure occurs, a System Trouble
E22-NN will result, where NN represents the zone number of the sensor in question. To
reset, press

C

to clear the display, enter the Function Menu, scroll to Reset Sensor

Watch Failure and press

U

.

If you cannot correct the problem, call for service



11.

Start Exit Time?

(Optional) (Start Exit Time programmed? ‰YES ‰NO)

In Commercial Burglary systems, exit delay may have been programmed to start after a
central-station “ringback” (verification) signal has been received. If the ringback tone has
not been received within about 30 seconds after arming, a communication problem may
exist. Use this function to start exit delay manually, then exit the premises immediately.
Be sure to have your alarm specialist check communications with the central station as
soon as possible.