Napco Security Technologies MAGNUM 825 User Manual

Page 4

Advertising
background image

lndicator Lights

ARMED/MEMORY (Red)

l

Steady- system is armed.

l

Flashes

-

alarm condition.

Flashes indicate the number of

zone(s) which were violated.

(see page 5, Key 2)

STATUS (Green)

l

Steady

-

system is disarmed, all

zones okay.

l

Flashes

-

a non-24 hour zone is

in trouble. Flashes indicate the
number of the zone(s) that are in

trouble. Note: to stop flashing
hold down Key 3 for two seconds,

SHUNT (Yellow)

Steady

-

one or more zones

manually shunted (bypassed).

NOTE: all three lights flashing to-
gether indicates that AC power has
been lost. Reset indication with
Key 9 (see page 5).

Mint-Sounder

l

Steady

Tone: day zone in trouble;

entry delay in progress; system
armed with a priority zone in trouble.

l

Beep (2 seconds): system armed

with any zone auto shunted; or
battery power low.

Arm-Disarm/Run/Load

Switch

l

Used to load (program-in) user

arm/disarm codes. Slide switch
to the right (LOAD) position when
entering codes (refer to Selecting
Your Codes on page 7).
Be sure to return theswitch to the
center (RUN) position after all

codes have been entered. Setting
this spring-return switch to the

left will also arm or disarm the

system (unless this option has
been removed). Your system
will not operate with the switch in
the LOAD position.

Advertising