Rear Wall

Cut-out Area

Optional Supply
Entrance

Mounting
Plate

Floor
Opening

Refrigerant
Line
Opening

Supply Air Duct

Cut Duct Opening
1/16th. Larger Than
Plenum Connector

Figure 7. Rear Mounting Plate

Rear Wall

Secure Duct Connector &
Mtg Plate With 2 Flat Head Screws
or Nails At Dimpled Locations

Refrigerant
Line
Opening

Supply Air Duct

Mounting
Plate

Plenum

Bend Connector Tabs
Under Duct Opening

Figure 8. Duct Connector (Non Platinum)

4. Secure duct connector to fl oor with two

fl at-head fasteners at dimpled locations
(see Figure 8).

5.

Secure connector to duct by bending bottom
tabs under and up against duct surfaces
(see Figure 10).

Method C
1. Attach tabs to sides of duct (one on each

side) using sheet metal fasteners or other
method, ensuring that the duct connector is
secure and sealed to the duct (see Figure
11).

2.

Seal the duct fl ap edges with an approved
tape or compound for a leak-free joint.

Method B
1.

Place duct connector through fl oor opening
with bottom tabs resting on top of supply
air duct. Mark cutout area around inside of
tabs.

2. Remove

duct connector and cut out duct

opening slightly larger than area marked.

3. If using optional rear mounting plate (sup-

plied with duct connector), install it to back
edge of fl oor opening (see Figure 7). Re-
install duct connector in fl oor opening. A
shim may be used, if necessary, to ensure
the furnace is level.