7 maintenance – Nilfisk-Advance America 5 User Manual

Page 13

Advertising
background image

12

english

1)

Options / model variants

POSEIDON 5

,

6.3 Rolling up the electrical

lead and storing
accessories

Risk of tripping!
To prevent accidents, always
carefully roll up the electrical
lead.

1. Wind up the high pressure

hose as illustrated.

2. Place the spray lance into

the spray lance storage.

6.4 Storing the cleaner

(below 0°C)

1. Store the cleaner in a dry

room without danger of frost
or protect as below:

CAUTION!
If the high-pressure cleaner is
stored in a room with tempera-
tures around or below 0°C, anti-
freeze should be drawn into the
pump beforehand:

1. Remove the water inlet hose

from the cleaner.

2. Remove the spray lance.
3. Switch on the cleaner with

the main switch in position „
I

“ and activate trigger on the

spray gun.
Switch off the cleaner after
max. 3 minutes.

4. Connect the suction hose to

the water inlet of the cleaner

and place it in a tank contain-
ing anti-freeze.

5. Switch on the cleaner with

the main switch in position „
I

„.

6. Hold the spray gun over the

tank containing anti-freeze
and operate it to start suc-
tion.

7. During suction operate the

spray gun two or three times.

8. Lift the suction hose from the

tank containing anti-freeze
and operate the spray gun to
pump off the remaining anti-
freeze.

9. Switching off the cleaner
10.To avoid any risks, store

the cleaner temporarily in a
heated room before using it
again.

7 Maintenance

7.1 Maintenance plan

Weekly

After the first 50

operating hours

Every six months

or 500 operating

hours

As

required

7.2.1 Cleaning water inlet filter

Q

Q

7.2.2 Checking pump oil level

Q

7.2.3 Changing pump oil

Q

Q

Advertising