7.2 Maintenance work
7.2.1 Cleaning water inlet

filter

A water filter is fitted on the water
inlet to prevent large particles of
dirt from entering into the pump.

1. Unscrew the quick-release

connection.

2. Remove the filter and rinse it.

Replace damaged filter. Re-
place damaged filter.

7.2.2 Checking the pump oil

level

1. Check whether the oil level

is between the minimum and
maximum marks. If neces-
sary, add oil (see chapter 9.4
for type of oil).

7.2.3 Changing the pump oil

1. Before changing the oil, al-

low the cleaner to become
warm.

2. Remove cover.
3. Loosen the hose clamp (A).
4. Remove the hose from the

hose nipple. Allow the oil to
drain into a suitable contain-
er (min. 1 l capacity) and dis-
pose of oil in compliance with
regulations.

5. Attach the hose and secure it

using the hose clamp.

6. Fill pump with fresh oil until

it appears between the MIN-
MAX marks.
Oil grade and capacity see
chapter ‘9.4 Technical Data’.
Check that no oil remains in
the expansion tank (Do not
overfill expansion tank).

7. Fix cover.

CAUTION!
Special pump oil is required if
the cleaner is used near food.
Please consult your Gerni deal-
er.