Network Computing Devices Label Printing Scale LSQ-40L User Manual

Page 5

Advertising
background image

SETTING UP THE SCALE FOR FIRST TIME

1). Carefully unpack scale from its box. Lift the indicators arm all the way up until
it stops. Adjust the correct angle of the indicator by loosening the black nut on the
arm next to the indicator. Move the indicator to the correct angle and then tighten
the nut. DO NOT over tighten.

2). Plug in the ac adapter to the wall socket and the other end into the scale. The
connector may appear tight on a new scale. You might try twisting the connector as
you are pushing it into the scales receptacle.

3). Turn on the scale. It should do a regressive countdown, then a label should
dispense. If the scale does not turn on, try twisting the connector again while
leaving the switch in the on position.

QUICK TEST OF THE PRINTER:

1). Remove the template from the main keyboard. There is a tab on the left side so it
can be pulled out. This exposes the programming keyboard.

2). Find the key(s) that came with the scale. Insert the key into the lock on the
bottom right of the scale. Turn it right 90 degrees.

3). The indicator should display PWD? Press the PRINT key. The scrolling message
should say PROGRAMMING MODE.

4). On the programming keyboard, press CONFIG. Using the arrow down button,
scroll down until it says MODE.

5). Press ENTER. The indicator should say AGENTS. Press ENTER.

6). Arrow up/dn until you see DISABLE. Press ENTER.

7). Arrow down until you see NON PLU. Press ENTER.

8). Arrow up/dn until you see ENABLE. Press ENTER.

9). Press ESC on the small keyboard until the scrolling message says
PROGRAMMING MODE again. Turn the key to the left and remove it.


Page 5


Advertising