11 figure 13. round duct connector installed, Table 4. roof jack assemblies, Figure 14. “a” & “b” cabinet furnaces – Nordyne Downflow Direct Vent Forced Air Gas Oil Furnaces SERIES M1B User Manual

Page 11

Advertising
background image

11

Figure 13. Round Duct Connector Installed

DUCT

CONNECTOR

MOUNTING

PLATE

SCREWS

FUEL

LINE

HOLES

14” SUPPLY

CONNECTION

Table 4. Roof Jack Assemblies

S

S

AW

T

27 47 - 2

AW= ALL WEATHER

FLASHING
PITCH/12" RISE
0=FLAT
2=2.5/12
4=4/12

MIN. ADJ.
LENGTH

F = FLAT FLASHING

S = SLANT FLASHING

TYPE:

BLANK = NON-TRANSIT

T= TRANSIT MODE

MAX. ADJ.
LENGTH

FLUE STEEL TYPE
A= ALUMINIZED
S=STAINLESS

MODEL NUMBER

APPROX. LENGTH

BELOW FLASHING

(F,S)AW(T)1523-(0,2,4)(A,S)

15” - 23”

(F,S)AW(T)2135-(0,2,4)(A,S)

21” - 35”

(F,S)AW(T)2747-(0,2,4)(A,S)

27” - 47”

(F,S)AW(T)3563-(0,2,4)(A,S)

35” - 63”

(F,S)AW(T)5195-(0,2,4)(A,S)

51” - 95”

MTG. PLATE TABS

SLIDE FURNACE

ALL THE WAY BACK

ONTO MTG. PLATE

SUPPLY AIR DUCT

Knockout Over Holes

SECURE FURNACE

WITH 2 FASTENERS AT FRONT

CORNER HOLES

Figure 14. “A” & “B” Cabinet Furnaces

FUEL LINE HOLES

MTG. PLATE TABS

SLIDE FURNACE

BACK AGAINST

MTG. PLATE

SECURE FURNACE

WITH 2 FASTENERS

AT FRONT CORNER HOLES

SUPPLY

AIR DUCT

Figure 15. “A” Cabinet Furnace on Coil

Cabinet

ROOF JACK INSTALLATION

Required ceiling and roof cut-out openings (see
Figure 11) must be carefully located to avoid
misalignment of the furnace and Roof Jack.
Note: Install only Roof Jack Assemblies listed
in Table 4 on this heating appliance.

Roof Jack Selection
1. Determine depth of ceiling cavity from center

of roof opening to center of ceiling opening.
(See Dimension “A” in Figure 16.)

2. Determine ceiling height and subtract height

of furnace. (See Dimension “B” in Figure 16.)

3. Add dimensions A + B (and X from Table 5

and Figure 18 if slant deck fl ashing is used).
The total length of (A + B + X) must be within
the minimum and maximum range of one of
the Roof Jacks listed in Table 4.

Application Notes:
• FAW, FAWT, SAW and SAWT Series Roof

Jacks with a 5” diameter inner vent pipe may
be used with all models of M1 Series gas and
M5 Series oil furnaces.

F = Flat Flashing: fl exes from 0/12 to 1/12 roof

slope. See Figure 17 (page 12).

S = Slant Flashing: 2.5/12 Slope fl exes from

1/12 to 4/12 roof slope, 4/12 fl exes from
3/12 to 5/12. See Figure 18.

• Stainless steel roof jacks are available.
• M1/M5 furnaces may be used with roof jacks

as tall as 170” (except M1M 056 & M1B 066
models, which are limited to 120”). An internal
roof jack extension (p/n 901935 - 10”, p/n
903107 - 18”) can be used to increase roof
jack height. All connections inside the home
must be made below the ceiling.

NOTE: If the roof jack crown is covered or blocked
with snow, the furnace will not operate properly.

Figure 16. Ceiling Cavity Depth

ROOF JACK

SLANT DECK

FLASHING

PITCHED

ROOF

CEILING

CEILING

CAVITY

Roof

Opening

"X" (SEE TABLE 5)

Flue Pipe

Combustion Air Pipe

56" or 76"

Furnace

“A”

“B”