Important – Nordyne Downflow Direct Vent Forced Air Gas Oil Furnaces SERIES M1B User Manual

Page 12

Advertising
background image

12

Figure 17. Example of Flat Jack

with Flashing

Figure 18. Example of 2½/12 Slant Jack

with Flashing

1. Locate center of Roof Jack opening, measure

13 1/2” from the rear wall of closet or alcove
along the center line of furnace and fl oor
opening. See Figure 19.

2. Cut ceiling and roof holes as follows:

• Ceiling = 8 3/4” (222 mm) diameter
• Roof = 9 3/8” (238 mm) diameter

IMPORTANT:

R e f e r t o t h e i n s t a l l a t i o n
i n s t r u c t i o n s p r o v i d e d w i t h
o p t i o n a l a i r c o n d i t i o n i n g
p a c k a g e s w h e n i n s t a l l i n g
f u r n a c e s w i t h o p t i o n a l c o o l i n g
c o i l c a b i n e t o r w i t h o p t i o n a l
C * s e r i e s i n d o o r c o i l s .

Table 5. Slant Deck Flashings

Optional Deck Flashings for Flat and 2.5/12 Pitch Roof Jacks. 4/12 Pitch Roof Jacks not applicable.

ROOF JACK SERIES

IF ROOF PITCH IS:

SLANT DECK

FLASHING NUMBER

“X” FACTOR

IS:

“F Series

2” in 12”

903893 (2.5/12)

2-1/8”

2-1/2” in 12”

903893 (2.5/12)

2-1/2”

3” in 12”

903894 (3/12)

2-7/8”

3-1/2” in 12”

903894 (3/12)

3-1/4”

4” in 12”

903895 (4/12)

3-5/8”

“S” Series (2.5 / 12

Pitch only)

4-1/2” in 12”

903895 (2.5/12)

2-1/8”

5” in 12”

903895 (2.5/12)

2-1/2”

5-1/2” in 12”

903894 (3/12)

2-7/8”

6” in 12”

903894 (3/12)

3-1/4”

6-1/2” in 12”

903895 (4/12)

3-5/8”

CEILING

CUT-OUT FOR

FLUE AND

ROOF JACK

C

L

C

L

24"

20"

13 1/2"

REAR WALL OF CLOSET OR ALCOVE

10"

FURNACE

OUTER

DOOR

FURNACE OUTLINE

Figure 19. Cut-Out Dimensions for

Flue & Roof Jack

If the home is located in regions where snow
accumulation exceeds 7” (HUD snowload zones)
use an external roof jack extension (p/n 901937).
Extensions are optional accessories and may be
purchased through your NORDYNE distributor.

Locating and Cutting Roof & Ceiling Openings
DO NOT ALLOW DEBRIS TO FALL INTO THE
FURNACE. THIS COULD CAUSE UNSAFE
OPERATION AND VOIDS THE FURNACE
WARRANTY. Use the top cap that comes with
the furnace packaging (or alternate protector) to
prevent debris from falling into the furnace before
the fi nal roof jack connection is made

Advertising