N-Link – Configuration, Continued…


Complex N-Link Configuration (Example):


Configuration Notes:

•

The Master and Slave must be part of the N-Ring topology.

•

If using default configuration choices, the administrator only needs to configure the N-Link Master.
The N-Link Slave and both Coupler switches will auto-detect any needed configuration.

•

If not using default configuration choices, the administrator may also need to configure the Default
Coupler port on the N-Link Slave.

•

There must be a direct link between the Master and Slave Control ports. Use of media converters or
other switches is not supported.

•

There must be a direct link between the Master and Slave Partner ports. Use of media converters or
other switches is not supported.

•

There must be at least one other switch, besides the Master and Slave, that supports N-Link on the
N-Ring.

•

N-Link will only support a single point of failure. Multiple points of failure and misconfiguration
are not supported and may cause a network storm under some circumstances.


Configuration Steps to redundantly couple 2 N-Ring networks:

1.

Ensure the Coupler and Control cables are disconnected at this point.

2.

Get Both N-Rings working with a status of OK.

3.

Configure N-Link Slave: Ensure that the N-Link Slave is set to Auto Configure and select a Default
Coupler Port. Save Configuration.

4.

Configure N-Link Master: Select the Control and Coupler ports. Save the Configuration.

5.

Connect the Control Link cable. Ensure that the Slave switch status now shows a state of “Slave”

6.

Connect the Coupler Link cables.

7.

Check N-Link status by selecting the N-Link Status View page.