Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide

Set Normal/Uplink Push Button

The Normal/Uplink push button on the front panel of the hub allows you to select the Uplink
(MDI) or Normal (MDI-X) position for port 8 on the Model DS508 hub, port 16 on the Model
DS516 hub, and port 24 on the Model DS524 hub. All other ports are wired Normal for direct
connection to PCs.

Select Normal if connecting a PC, server, or router to the port. Select Uplink if connecting a hub
or switch. The Normal/Uplink push button eliminates the need to use a crossover cable.

When installation is complete and power has been applied to the hub, the following conditions
should exist:

Power LED is on.

Link LED on each connected port is on.

Utilization LEDs on the front panel are blinking when data is being received by any port in
the hub, and the Link/Receive LED on the connected port is blinking when data is being
received by that port.

With a single hub, the Terminator and Bridge LEDs in the rear panel are on.

With a stack of hubs, the Terminator LEDs in the top and bottom hubs are on. The Bridge
LED in the bottom hub is on.

If there are any problems, refer to the Troubleshooting table.

Caution:

100 Mbps operation requires the use of Category 5 UTP wiring with 100 Mbps

certified connectors. NETGEAR highly recommends using Category 5 cable so your
network can operate at either 10 or 100 Mbps.

Connect a PC to the Hub

8094FA

Normal/U

plink

24

12

Link

RX

Link

RX

17

5

Power D

ata Collis

ion

Power

Data Collisio

n

Verify Your Installation