Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide

Rear Panel

The rear panel of a Model DS508, Model DS516, and Model DS524 hub has two LEDs, one
labeled Terminator and one labeled 10/100 Mbps Bridge. The Terminator LED indicates whether
or not the built-in terminator in that hub is active (the built-in terminator eliminates the need for an
external terminator). The 10/100 Mbps Bridge LED indicates which hub has the active bridge.

Before you begin installing the hubs, prepare the installation site. Make sure your operating
environment meets the operating environment requirements of the equipment.

Characteristic Requirement

Temperature

Ambient temperature between 0

°

and 40

°

C

(32

°

and 104

°

F). No nearby heat sources such as

direct sunlight, warm air exhausts, or heaters.

Humidity

90% maximum relative humidity, noncondensing.

Ventilation

Minimum 2 inches (5.08 cm) on all sides for cooling.
Adequate airflow in room or wiring closet.

Operating
conditions

At least 6 feet (1.83 m) to nearest source of electromagnetic noise (such as
photocopy machine
or arc welder).

Service access

Minimum 12 inches (19.68 cm) front and back for service access and
maintenance.
Front and back clearance for cables and wiring hardware such as punchdown
blocks.

Power

Adequate power source within 6 feet (1.83 m).

Tabletop
requirements

Flat area approximately 13.0 inches (33.0 cm) by
8.0 inches (20.3 cm).

Rear Panel of the Model DS508, Model DS516,

and Model DS524 Hubs

100-240 VAC 50-60 Hz 0.5A

Terminator

Cascade Down

Cascade Up

10/100 Mbps

Bridge

8153FA

Terminator LED

10/100 Mbps Bridge LED

Cascade Up connector

Cascade Down connector

Power receptacle

8152FA

100M

10M

vista RJ-45

network ports

Site Preparation